MODEL CLLP100-W1V48 CLLP100-W1V24 CLLP100-W1V12
 

 

Output

 

 

Rated voltage 48V 24V 12V
No-load voltage No more than 48.4V No more than 24.4V No more than 12.4V
Output voltage error 48V±1% 24V±2% 12V±4%
Rated output current 2.08A 4.16A 8.3A
Output current range 0~2.08A 0~4.16.A 0~8.3A
Rated output power 100W 100W 100W
THD ≤15% ≤15% ≤15%
Ripple and noise 150mVp-p 120mVp-p 100mVp-p
PFC 0.97-0.99 0.97-0.99 0.97-0.99
 

 

Input

 

Input voltage range AC 90V~264V AC;50Hz~60Hz;
AC input current 1.0A/115V~0.5A/230V
Cold start current 40A/230VAC
efficiency 93% 92% 92%
Start, rise, hold time 1000ms,50ms,20ms
Quiescent current <3.5mA/240VAC
 

Protection characteristics

overload protection 105-135% hiccup mode with a rated power of 100W, the circuit returns to normal after the abnormal conditions are removed
Over-current protection When the voltage is greater than the maximum voltage, the circuit will be protected. When the abnormality is removed, the circuit will return to normal
Short circuit protection Short circuit more than 3 times, no damage, automatic recovery
Over-temperature protection Start protection at 105 degrees C, and the circuit output is normal after the temperature returns to normal.
environment Operating temperature; humidity -20℃~60℃;20%~90%RH
Storage temperature; humidity -40℃~85℃;10%~95%RH
Seismic performance 10-500hz 2G 10.min/1 cycle, 60 minutes for each axis
Safty Withstand voltage performance Between input and output:3KV /AC 60S
standards safety standards Conform to IEC60950-1; EN60950-1;EN62321-1
EMC standards Conform to EN55032; EN55015 CLASS B;
packing Weight
Packing method
The net weight of the product is 0.28 kg

35cm X 22cm X27.5 cm/ 36 PCS

 

Special instructions, 1. All parameters are measured under AC 220 V voltage input, rated load and 25 ℃ when not specified;
2. Ripple and noise voltage are measured at the end of 12 "twisted pair with 0.1uF and 47uF at 20MHz bandwidth oscilloscope;